Design and implementation of a power quality disturbance classifier: An Al approach

Citation

Reaz, , M. B. I and Choong, , F and Sulaiman, , M. S and Mohd-, Yasin, F. (2006) Design and implementation of a power quality disturbance classifier: An Al approach. Source: JOURNAL OF INTELLIGENT & FUZZY SYSTEMS , 17 (6). pp. 623-631. ISSN 1064-1246

Full text not available from this repository.

Abstract

This paper presents a new intelligent system incorporating wavelet transform, artificial neural network and fuzzy logic to automate the classification of power quality disturbance. This novel and efficient method in hardware, based on FPGA technology showed improved performance over existing approaches for power quality disturbance detection and classification on six types of disturbances including sag, swell, transient, fluctuation, interruption and normal waveform. The approach obtained an average classification accuracy of 98.19%. The design was successfully implemented, tested and validated on Altera APEX EP20K200EBC652-1X FPGA utilizing 1209 logic cells and achieved a maximum frequency of 263.71 MHz.

Item Type: Article
Subjects: Q Science > QA Mathematics > QA71-90 Instruments and machines > QA75.5-76.95 Electronic computers. Computer science
Divisions: Faculty of Engineering (FOE)
Depositing User: Ms Rosnani Abd Wahab
Date Deposited: 10 Aug 2011 07:38
Last Modified: 10 Aug 2011 07:38
URII: http://shdl.mmu.edu.my/id/eprint/2077

Downloads

Downloads per month over past year

View ItemEdit (login required)