Citation
Moradi, Farhad and Jalili, M. and Saraee, Kh Rezaee Ebrahim and Abdi, M. R. and Abdul Rashid, Hairul Azhar (2024) Radiation shielding assessment for interventional radiology personnel: Geant4 dosimetry of lead-free compositions. Biomedical Physics & Engineering Express, 10 (2). 025029. ISSN 2057-1976
Text
7.pdf - Published Version Restricted to Repository staff only Download (1MB) |
Abstract
The inherent biological hazards associated with ionizing radiation necessitate the implementation of effective shielding measures, particularly in medical applications. Interventional radiology, in particular, poses a unique challenge as it often exposes medical personnel to prolonged periods of high x-ray doses. Historically, lead and lead-based compounds have been the primary materials employed for shielding against photons. However, the drawbacks of lead, including its substantial weight causing personnel’s inflexibility and its toxicity, have raised concerns regarding its long-term impact on both human health and the environment. Barium tantalate has emerged as a promising alternative, due to its unique attenuation properties against low-energy x-rays, specifically targeting the weak absorption area of lead. In the present study, we employ the Geant4 Monte Carlo simulation tool to investigate various formulations of barium tantalate doped with rare earth elements. The aim is to identify the optimal composition for shielding x-rays in the context of interventional radiology. To achieve this, we employ a reference x-ray spectrum typical of interventional radiology procedures, with energies extending up to 90 keV, within a carefully designed simulation setup. Our primary performance indicator is the reduction in air kerma transmission. Furthermore, we assess the absorbed doses to critical organs at risk within a standard human body phantom protected by the shield. Our results demonstrate that specific concentrations of the examined rare earth impurities can enhance the shielding performance of barium tantalate. To mitigate x-ray exposure in interventional radiology, our analysis reveals that the most effective shielding performance is achieved when using barium tantalate compositions containing 15% Erbium or 10% Samarium by weight. These findings suggest the possibility of developing lead-free shielding solutions or apron for interventional radiology personnel, offering a remarkable reduction in weight (exceeding 30%)while maintaining shielding performance at levels comparable to traditional lead-based materials.
Item Type: | Article |
---|---|
Uncontrolled Keywords: | Monte Carlo |
Subjects: | T Technology > T Technology (General) > T201 Patents. Trademarks |
Divisions: | Faculty of Engineering (FOE) |
Depositing User: | Ms Nurul Iqtiani Ahmad |
Date Deposited: | 04 Mar 2024 01:27 |
Last Modified: | 04 Mar 2024 01:27 |
URII: | http://shdl.mmu.edu.my/id/eprint/12143 |
Downloads
Downloads per month over past year
Edit (login required) |